NO
|
Name
Of Operation
|
Power
|
Select SW
|
Shift Lever
|
MIR
Position
|
Manual Control
|
Result
|
L
|
R
|
1
|
Basic
Operation
|
IGN
|
LH
|
Not-R
|
A
POS.
|
B
POS.
|
Shift
lever Not-R→R
|
MIR L:Auto reverse
to (A-5°) POS.
|
MIR R:Auto reverse
to (B-5°) POS.
|
2
|
IGN
|
RH
|
Not-R
|
A
POS.
|
B
POS.
|
Shift
lever Not-R → R
|
MIR L:No
Change.
|
MIR R:Auto reverse
to (B-5°) POS.
|
3
|
IGN
|
N
|
Not-R
|
A
POS.
|
B
POS.
|
Shift
lever Not-R →R
|
MIR L:No
Change
|
MIR R:No
Change
|
4
|
Return after basic
operation
|
IGN
|
LH
|
R
|
RESULT OF
1
|
RESULT OF
1
|
Shift
lever R→ Not-R
|
MIR L:Return to (A)
position
|
MIR R:Return to (B)
position
|
5
|
IGN
|
RH
|
R
|
A
POS.
|
RESULT OF
2
|
Shift
lever R→Not-R
|
MIR L:No
Change
|
MIR R:Return to (B)
position
|
6
|
Mirror switch is
operated during auto reverse
|
IGN
|
LH
|
Not-R →
R
|
During FUNC.
1
|
During FUNC.
1
|
Mirror
Switch Control
|
MIR L:BY Mirror
Switch Operation
|
MIR R:Auto reverse
to (B-5°) POS
|
7
|
IGN
|
RH
|
Not-R →
R
|
A
POS.
|
During FUNC.
2
|
Mirror
Switch Control
|
MIR L:No
Change
|
MIR R:BY Mirror
Switch Operation
|
8
|
Receive return
signal after mirror switch control during
autoreverse
|
IGN
|
LH
|
R
|
Complete
FUN.6
|
Complete
FUN.6
|
Shift
lever R→Not-R
|
MIR L:Return to (A)
position
|
MIR R:Return to (B)
position
|
9
|
IGN
|
RH
|
R
|
A
POS.
|
Complete
FUN.7
|
Shift
lever R→Not-R
|
MIR L:No
Change
|
MIR R:Return to (B)
position
|
10
|
Mirror switch is
operated during return to origin
|
IGN
|
LH
|
R→
Not-R
|
During FUNC.
4
|
During FUNC.
4
|
Mirror
Switch Control
|
MIR L:BY Mirror
Switch Operation
|
MIR R:Return to (B)
position
|
11
|
IGN
|
RH
|
R→
Not-R
|
A
POS.
|
During FUNC.
5
|
Mirror
Switch Control
|
MIR L:No
Change
|
MIR L:BY Mirror
Switch Operation
|
12
|
Select switch is
changed during auto reverse
|
IGN
|
LH
|
Not-R →
R
|
During FUNC.
1
|
During FUNC.
1
|
Change select
switch to N
|
MIR L:Return to (A)
position AFTER 500ms
|
MIR R:Return to (B)
position AFTER 500ms
|
13
|
IGN
|
LH
|
Not-R →
R
|
During FUNC.
1
|
During FUNC.
1
|
Select Switch
LH→N(Within 500ms)→RH
|
MIR L:Auto reverse
to (A-5°) POS.
|
MIR R:Auto reverse
to (B-5°) POS.
|
14
|
IGN
|
LH
|
Not-R →
R
|
During FUNC.
1
|
During FUNC.
1
|
Select Switch
LH→N(After 500ms)→RH
|
MIR L:Return to (A)
position
|
MIR R:Auto reverse
to (B-5°) POS
|
15
|
IGN
|
RH
|
Not-R →
R
|
A
POS.
|
During FUNC.
2
|
Change select
switch to N
|
MIR L:No
Change
|
MIR R:Return to (B)
position AFTER 500ms
|
16
|
IGN
|
RH
|
Not-R →
R
|
A
POS.
|
During FUNC.
2
|
Select
Switch RH→N→LH
|
MIR L:Auto reverse
to (A-5°) POS.
|
MIR R:Auto reverse
to (B-5°) POS.
|
17
|
IGN
|
N
|
Not-R →
R
|
A
POS.
|
B
POS.
|
Select
Switch N→LH
|
MIR L:Auto reverse
to (A-5°) POS.
|
MIR R:Auto reverse
to (B-5°) POS.
|
18
|
IGN
|
N
|
Not-R →
R
|
A
POS.
|
B
POS.
|
Select
Switch N→LH
|
MIR L:No
Change
|
MIR R:Auto reverse
to (B-5°) POS
|
19
|
IGN off during auto
reverse
|
IGN
|
LH
|
Not-R →
R
|
During FUNC.
1
|
During FUNC.
1
|
IGN→ACC or
B+
|
MIR L:Return to (A)
position
|
MIR R:Return to (B)
position
|
20
|
IGN
|
RH
|
Not-R →
R
|
A
POS.
|
During FUNC.
2
|
IGN→ACC or
B+
|
MIR L:No
Change
|
MIR R:Return to (B)
position
|
21
|
IGN off after
completing auto reverse
|
IGN
|
LH
|
Not-R →
R
|
Complete
FUN.1
|
Complete
FUN.1
|
IGN→ACC or
B+
|
MIR L:Return to (A)
position
|
MIR R:Return to (B)
position
|
22
|
IGN
|
RH
|
Not-R →
R
|
A
POS.
|
Complete
FUN.2
|
IGN→ACC or
B+
|
MIR L:No
Change
|
MIR R:Return to (B)
position
|
23
|
IGN off during
return to origin
|
IGN
|
LH
|
R →
Not-R
|
During FUNC.
4
|
During FUNC.
4
|
IGN→ACC or
B+
|
MIR L:Return to (A)
position
|
MIR R:Return to (B)
position
|
24
|
IGN
|
RH
|
R →
Not-R
|
A
POS.
|
During FUNC.
5
|
IGN→ACC or
B+
|
MIR L:No
Change
|
MIR R:Return to (B)
position
|
25
|
IGN is on during
return to origin by being off of IGN
|
IGN→ACC or
B+
|
LH
|
R
|
During FUNC.
23
|
During FUNC.
23
|
(Shift lever
R→Not-R) and next (ACC or B+→IGN)
|
MIR L:Return to (A)
position
|
MIR R:Return to (B)
position
|
26
|
IGN→ACC or
B+
|
LH
|
R
|
During FUNC.
23
|
During FUNC.
23
|
ACC or B+
→IGN
|
MIR L:Auto reverse
to (A-5°) POS.
|
MIR R:Auto reverse
to (B-5°) POS.
|
27
|
IGN→ACC or
B+
|
RH
|
R
|
A
POS.
|
During FUNC.
24
|
(Shift lever
R→Not-R) and next (ACC or B+→IGN)
|
MIR L:No
Change
|
MIR R:Return to (B)
position
|
28
|
IGN→ACC or
B+
|
RH
|
R
|
A
POS.
|
During FUNC.
24
|
ACC or B+
→IGN
|
MIR L:No
Change
|
MIR R:Auto reverse
to (B-5°) POS.
|
29
|
In case of
IMS-position switch input during mirror reverse operation, if
in inhibit condition then operating the return acts else in
play back condition then replay acts.
|
30
|
The position A,B of
mirror is operated by mirror switch or by IMS
memorized.
|
31
|
If the current
position of mirror is different from memorized A,B in clause
30 when IGN ON→OFF, it's recovered to MIR L:(A).R:(B)
position.
|
32
|
IGN on status, if
the current position of mirror is different from memorized A,B
in clause 30 when mirror select SW is changed to LH→N or RH→N,
it's recovered to MIR L:(A).R:(B) position.
|
33
|
In case of changing
'R' '0' → '1', operation is done after 350 ± 50
msec.
|